{"id":533,"date":"2024-04-01T09:00:16","date_gmt":"2024-04-01T09:00:16","guid":{"rendered":"https:\/\/www.candoifp.com\/blog\/?p=533"},"modified":"2025-11-17T20:23:20","modified_gmt":"2025-11-17T20:23:20","slug":"fire-sprinkler-corrosion-solutions","status":"publish","type":"post","link":"https:\/\/www.candoifp.com\/blog\/2024\/04\/01\/fire-sprinkler-corrosion-solutions\/","title":{"rendered":"Fire Sprinkler Corrosion"},"content":{"rendered":"<h1><b>Fire Sprinkler Corrosion Solutions<\/b><\/h1>\n<p><span style=\"font-weight:400;\">You know that protecting your property with a fire sprinkler system is a legal requirement and an important protection against property loss, but what happens when those systems fail due to corrosion? Corrosion threatens the reliability of automatic fire sprinklers, and unfortunately, the presence of water, iron, and other metals in systems makes it nearly impossible to avoid. Fire sprinkler corrosion eats away at pipes from the inside out, often escaping notice until it\u2019s already caused extensive and costly damage.<\/span><\/p>\n<h2><span style=\"font-weight:400;\">What Causes Fire Sprinkler Corrosion?\u00a0<\/span><\/h2>\n<p><span style=\"font-weight:400;\">According to the <\/span><a href=\"https:\/\/www.ifma-afc.org\/docs\/submissions\/20160718_AFC_PotterCorrosionSolutions.pdf\"><span style=\"font-weight:400;\">Corrosion in Fire Sprinkler Systems<\/span><\/a><span style=\"font-weight:400;\"> report, 73% of dry sprinkler systems experience significant corrosion problems after 12.5 years. The problem manifests as orange-red rust that quickly corrodes metal pipes from within. This process creates an ideal environment for microbiologically influenced corrosion (MIC), which obstructs pipes with tubercules, leading to holes and other problems. It is important to catch corrosion problems early on, implement effective corrosion solutions, and fix problems before they become costly repairs.<\/span><\/p>\n<p><span style=\"font-weight:400;\">Photo by Jeremy Deen<\/span><\/p>\n<h2><span style=\"font-weight:400;\">How Does Corrosion Affect a Fire Sprinkler System?\u00a0<\/span><\/h2>\n<p><span style=\"font-weight:400;\">Corrosion can lead to holes and leaks, rust buildup that limits the flow of water, corroded fire sprinkler heads, and eventually fire sprinkler failure. Left untreated, it\u2019s only a matter of time until corrosion triggers leaks or accidental sprinkler discharges that can cause tens of thousands of dollars in water damage to the property the system was meant to protect. Even worse, it can cause fire sprinklers to fail during a fire, putting lives at risk. Corroded fire sprinkler heads affect the deflector and discharge pattern or completely seal the plug, preventing water from reaching the fire. Implementing a corrosion solution is an important part of maintaining your sprinkler system.\u00a0<\/span><\/p>\n<h2><span style=\"font-weight:400;\">Should You Repair or Replace Corroded Sprinkler Pipes?<\/span><\/h2>\n<p><span style=\"font-weight:400;\">In the past, the standard approach to fire sprinkler corrosion solutions has been to repair only the affected pipes. While repairs can patch smaller issues, such as pinhole leaks, they may leave the larger problem untreated. No matter which of the many corrosion solutions you implement, remember that the goal is to maintain sprinkler pipes free of corrosion to the extent possible, which can significantly impact their longevity and functionality.<\/span><\/p>\n<h3><span style=\"font-weight:400;\">NFPA 25 Guidelines For Fixing Corroded Sprinkler Pipes<\/span><\/h3>\n<p><span style=\"font-weight:400;\">Property owners must balance many factors and options when considering what corrosion solutions to implement. Fortunately, <\/span><a href=\"https:\/\/www.nfpa.org\/codes-and-standards\/nfpa-25-standard-development\/25\"><span style=\"font-weight:400;\">NFPA 25<\/span><\/a><span style=\"font-weight:400;\"> provides guidelines for corrosion solutions, including when to consider repair or replacement. These guidelines also allow for a degree of judgment when you are deciding how to address the problem.\u00a0<\/span><\/p>\n<ul>\n<li style=\"font-weight:400;\"><b>Class I:<\/b><span style=\"font-weight:400;\"> Little damage is found; the pipe array should simply be flushed, which involves using a pressurized water source to clear sprinkler systems of potential blockages.\u00a0<\/span><\/li>\n<li style=\"font-weight:400;\"><b>Class II: <\/b><span style=\"font-weight:400;\">Medium damage is found, meaning some but not all pipes show increased damage. Those specific pipes should be replaced.<\/span><\/li>\n<li style=\"font-weight:400;\"><b>Class III: <\/b><span style=\"font-weight:400;\">Considerable corrosion and deposits are present; the complete pipe array or significant parts of it should be replaced.<\/span><\/li>\n<\/ul>\n<h3><span style=\"font-weight:400;\">Factors to Consider When Choosing a Corrosion Solution\u00a0<\/span><\/h3>\n<p><span style=\"font-weight:400;\">Let\u2019s consider four main factors that can impact your decision when considering which of the various corrosion solutions would work for your property.<\/span><\/p>\n<ul>\n<li style=\"font-weight:400;\"><b>Cost:<\/b><span style=\"font-weight:400;\"> Replacing sprinkler pipes that stretch throughout a property is no small task, incurring high costs and potential business interruptions. Many property owners opt to simply repair fire sprinkler leaks until they become such a nuisance or expense that they need a better solution.<\/span><\/li>\n<li style=\"font-weight:400;\"><b>History of problems:<\/b><span style=\"font-weight:400;\"> If you are repairing corrosion-related leaks frequently, you will ultimately save money by replacing the pipes.\u00a0<\/span><\/li>\n<li style=\"font-weight:400;\"><b>System age:<\/b><span style=\"font-weight:400;\"> The remaining useful life of the sprinkler system is a significant factor when evaluating whether repair or replacement is the right choice. You should also consider the advancements in fire sprinkler technology since the system was installed.\u00a0<\/span><\/li>\n<li style=\"font-weight:400;\"><b>Extent of the damage:<\/b><span style=\"font-weight:400;\"> Corrosion located in a spot that makes it difficult to just replace a section of a system matters as well. Sometimes corrosion becomes so invasive that a full system replacement is the only option, but it\u2019s important to note that localized corrosion doesn\u2019t generally warrant such extensive measures. Surgical replacement of the failing piping can often fix the problem, followed by implementing a corrosion solution strategy.<\/span><\/li>\n<\/ul>\n<h2><span style=\"font-weight:400;\">Strategies for Corrosion Solutions and Management\u00a0<\/span><\/h2>\n<p><span style=\"font-weight:400;\">Corrosion remains one of the biggest challenges facing the fire protection industry and unfortunately, no fire sprinkler system is completely immune to it. However, many property owners fail to take corrosion solution measures to mitigate the problem until significant damage is detected. A <\/span><a href=\"https:\/\/www.candoifp.com\/corrosion-management.php\"><span style=\"font-weight:400;\">corrosion management<\/span><\/a><span style=\"font-weight:400;\"> strategy is key to avoiding expensive repairs and replacements in the future.<\/span><\/p>\n<p><span style=\"font-weight:400;\">To mitigate the risk of fire sprinkler failure due to corroded fire sprinkler heads, implementing comprehensive corrosion solutions is essential. Regular inspections, proactive maintenance, and investing in corrosion-resistant materials are key strategies to prevent the deterioration of fire sprinkler components. By addressing corrosion issues promptly and employing effective preventive measures, you can ensure the reliability and functionality of their fire sprinkler systems, safeguarding lives and property against the devastating impact of fire incidents.<\/span><\/p>\n<h3><span style=\"font-weight:400;\">The Role of Inspections in Corrosion Prevention\u00a0<\/span><\/h3>\n<p><span style=\"font-weight:400;\">NFPA 25 also requires internal inspections of sprinkler piping every five years or as needed to monitor corrosion levels. Regular inspection and testing of sprinkler systems are critical to catching corrosion at its earliest stages and preventing costly damage or, worse, system failure during a fire.\u00a0<\/span><\/p>\n<h3><span style=\"font-weight:400;\">Use Corrosion Resistant Sprinkler Heads\u00a0<\/span><\/h3>\n<p><span style=\"font-weight:400;\">If your environment demands it, make sure your fire sprinkler system stands ready to suppress fires for years to come by investing in corrosion-resistant sprinkler heads. Fire sprinklers listed for use in corrosive environments are either made of non-corroding materials such as stainless steel or have corrosion-retarding finishes or coatings like polyester paint, nickel, PTFE, wax, lead, or others.<\/span><\/p>\n<h3><span style=\"font-weight:400;\">Vents and Corrosion Monitoring\u00a0<\/span><\/h3>\n<p><span style=\"font-weight:400;\">To prevent fire sprinkler failure caused by corroded fire sprinkler heads, implement corrosion solutions such as installing air vents in wet systems and considering corrosion monitoring. Air vents help release trapped air in wet sprinkler pipes, reducing oxygen corrosion. These vents can be manual or automatic and should be located near high points in the system. Additionally, corrosion monitoring in environments prone to corrosive activity enables early detection of corrosion, preventing costly repairs and system failures. Monitoring solutions continuously assess metal loss or gas composition, issuing alerts at the first signs of corrosive activity.<\/span><\/p>\n<h3><span style=\"font-weight:400;\">Nitrogen Inerting Corrosion Solutions<\/span><\/h3>\n<p><span style=\"font-weight:400;\">A growing trend in corrosion solutions is stripping the pressurized air from dry sprinklers and replacing it with nitrogen, which dramatically increases the lifespan of dry piping. Nitrogen is an inert gas, meaning it doesn\u2019t undergo the chemical reactions that lead to electrochemical corrosion. Creating an oxygen-free environment in sprinkler pipes enables them to last longer, regardless of whether water is present. It also makes a dramatic difference in long-term maintenance, repair, and replacement costs over the life of a building.\u00a0<\/span><\/p>\n<p><span style=\"font-weight:400;\">By understanding the causes of corrosion, investing in proactive maintenance, and considering innovative solutions like nitrogen inerting, you can protect your property from the devastating effects of corroded fire sprinkler heads. Don\u2019t wait until it\u2019s too late; take action today to ensure the safety and security of your building for years to come.<\/span><\/p>\n","protected":false},"excerpt":{"rendered":"<p>Fire Sprinkler Corrosion Solutions You know that protecting your property with a fire sprinkler system is a legal requirement and an important protection against property loss, but what happens when those systems fail due to corrosion? Corrosion threatens the reliability&hellip; <a href=\"https:\/\/www.candoifp.com\/blog\/2024\/04\/01\/fire-sprinkler-corrosion-solutions\/\" class=\"more-link\">Continue Reading <span class=\"meta-nav\">&rarr;<\/span><\/a><\/p>\n","protected":false},"author":4,"featured_media":0,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[1],"tags":[],"class_list":["post-533","post","type-post","status-publish","format-standard","hentry","category-news"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.5 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Fire Sprinkler Corrosion | International Fire Protection<\/title>\n<meta name=\"description\" content=\"Protect your property with fire sprinkler corrosion solutions. Learn the causes of corrosion and strategies to prevent fire sprinkler failure.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.candoifp.com\/blog\/2024\/04\/01\/fire-sprinkler-corrosion-solutions\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Fire Sprinkler Corrosion | International Fire Protection\" \/>\n<meta property=\"og:description\" content=\"Protect your property with fire sprinkler corrosion solutions. Learn the causes of corrosion and strategies to prevent fire sprinkler failure.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.candoifp.com\/blog\/2024\/04\/01\/fire-sprinkler-corrosion-solutions\/\" \/>\n<meta property=\"og:site_name\" content=\"International Fire Protection Blog\" \/>\n<meta property=\"article:published_time\" content=\"2024-04-01T09:00:16+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2025-11-17T20:23:20+00:00\" \/>\n<meta name=\"author\" content=\"Julie\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Julie\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"6 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.candoifp.com\\\/blog\\\/2024\\\/04\\\/01\\\/fire-sprinkler-corrosion-solutions\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.candoifp.com\\\/blog\\\/2024\\\/04\\\/01\\\/fire-sprinkler-corrosion-solutions\\\/\"},\"author\":{\"name\":\"Julie\",\"@id\":\"https:\\\/\\\/www.candoifp.com\\\/blog\\\/#\\\/schema\\\/person\\\/85dcedf1e8469366bdf8cb4e8b51c97f\"},\"headline\":\"Fire Sprinkler Corrosion\",\"datePublished\":\"2024-04-01T09:00:16+00:00\",\"dateModified\":\"2025-11-17T20:23:20+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.candoifp.com\\\/blog\\\/2024\\\/04\\\/01\\\/fire-sprinkler-corrosion-solutions\\\/\"},\"wordCount\":1188,\"articleSection\":[\"News\"],\"inLanguage\":\"en-US\"},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.candoifp.com\\\/blog\\\/2024\\\/04\\\/01\\\/fire-sprinkler-corrosion-solutions\\\/\",\"url\":\"https:\\\/\\\/www.candoifp.com\\\/blog\\\/2024\\\/04\\\/01\\\/fire-sprinkler-corrosion-solutions\\\/\",\"name\":\"Fire Sprinkler Corrosion | International Fire Protection\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.candoifp.com\\\/blog\\\/#website\"},\"datePublished\":\"2024-04-01T09:00:16+00:00\",\"dateModified\":\"2025-11-17T20:23:20+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/www.candoifp.com\\\/blog\\\/#\\\/schema\\\/person\\\/85dcedf1e8469366bdf8cb4e8b51c97f\"},\"description\":\"Protect your property with fire sprinkler corrosion solutions. Learn the causes of corrosion and strategies to prevent fire sprinkler failure.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.candoifp.com\\\/blog\\\/2024\\\/04\\\/01\\\/fire-sprinkler-corrosion-solutions\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.candoifp.com\\\/blog\\\/2024\\\/04\\\/01\\\/fire-sprinkler-corrosion-solutions\\\/\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.candoifp.com\\\/blog\\\/2024\\\/04\\\/01\\\/fire-sprinkler-corrosion-solutions\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/www.candoifp.com\\\/blog\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Fire Sprinkler Corrosion\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/www.candoifp.com\\\/blog\\\/#website\",\"url\":\"https:\\\/\\\/www.candoifp.com\\\/blog\\\/\",\"name\":\"International Fire Protection Blog\",\"description\":\"\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/www.candoifp.com\\\/blog\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/www.candoifp.com\\\/blog\\\/#\\\/schema\\\/person\\\/85dcedf1e8469366bdf8cb4e8b51c97f\",\"name\":\"Julie\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/6f93f7901e679dc73c0ebc994ad2dc26f932dbddc508ded57ad48bf938dc4e1a?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/6f93f7901e679dc73c0ebc994ad2dc26f932dbddc508ded57ad48bf938dc4e1a?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/6f93f7901e679dc73c0ebc994ad2dc26f932dbddc508ded57ad48bf938dc4e1a?s=96&d=mm&r=g\",\"caption\":\"Julie\"},\"url\":\"https:\\\/\\\/www.candoifp.com\\\/blog\\\/author\\\/jheltunen\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Fire Sprinkler Corrosion | International Fire Protection","description":"Protect your property with fire sprinkler corrosion solutions. Learn the causes of corrosion and strategies to prevent fire sprinkler failure.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.candoifp.com\/blog\/2024\/04\/01\/fire-sprinkler-corrosion-solutions\/","og_locale":"en_US","og_type":"article","og_title":"Fire Sprinkler Corrosion | International Fire Protection","og_description":"Protect your property with fire sprinkler corrosion solutions. Learn the causes of corrosion and strategies to prevent fire sprinkler failure.","og_url":"https:\/\/www.candoifp.com\/blog\/2024\/04\/01\/fire-sprinkler-corrosion-solutions\/","og_site_name":"International Fire Protection Blog","article_published_time":"2024-04-01T09:00:16+00:00","article_modified_time":"2025-11-17T20:23:20+00:00","author":"Julie","twitter_card":"summary_large_image","twitter_misc":{"Written by":"Julie","Est. reading time":"6 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.candoifp.com\/blog\/2024\/04\/01\/fire-sprinkler-corrosion-solutions\/#article","isPartOf":{"@id":"https:\/\/www.candoifp.com\/blog\/2024\/04\/01\/fire-sprinkler-corrosion-solutions\/"},"author":{"name":"Julie","@id":"https:\/\/www.candoifp.com\/blog\/#\/schema\/person\/85dcedf1e8469366bdf8cb4e8b51c97f"},"headline":"Fire Sprinkler Corrosion","datePublished":"2024-04-01T09:00:16+00:00","dateModified":"2025-11-17T20:23:20+00:00","mainEntityOfPage":{"@id":"https:\/\/www.candoifp.com\/blog\/2024\/04\/01\/fire-sprinkler-corrosion-solutions\/"},"wordCount":1188,"articleSection":["News"],"inLanguage":"en-US"},{"@type":"WebPage","@id":"https:\/\/www.candoifp.com\/blog\/2024\/04\/01\/fire-sprinkler-corrosion-solutions\/","url":"https:\/\/www.candoifp.com\/blog\/2024\/04\/01\/fire-sprinkler-corrosion-solutions\/","name":"Fire Sprinkler Corrosion | International Fire Protection","isPartOf":{"@id":"https:\/\/www.candoifp.com\/blog\/#website"},"datePublished":"2024-04-01T09:00:16+00:00","dateModified":"2025-11-17T20:23:20+00:00","author":{"@id":"https:\/\/www.candoifp.com\/blog\/#\/schema\/person\/85dcedf1e8469366bdf8cb4e8b51c97f"},"description":"Protect your property with fire sprinkler corrosion solutions. Learn the causes of corrosion and strategies to prevent fire sprinkler failure.","breadcrumb":{"@id":"https:\/\/www.candoifp.com\/blog\/2024\/04\/01\/fire-sprinkler-corrosion-solutions\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.candoifp.com\/blog\/2024\/04\/01\/fire-sprinkler-corrosion-solutions\/"]}]},{"@type":"BreadcrumbList","@id":"https:\/\/www.candoifp.com\/blog\/2024\/04\/01\/fire-sprinkler-corrosion-solutions\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.candoifp.com\/blog\/"},{"@type":"ListItem","position":2,"name":"Fire Sprinkler Corrosion"}]},{"@type":"WebSite","@id":"https:\/\/www.candoifp.com\/blog\/#website","url":"https:\/\/www.candoifp.com\/blog\/","name":"International Fire Protection Blog","description":"","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.candoifp.com\/blog\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Person","@id":"https:\/\/www.candoifp.com\/blog\/#\/schema\/person\/85dcedf1e8469366bdf8cb4e8b51c97f","name":"Julie","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/secure.gravatar.com\/avatar\/6f93f7901e679dc73c0ebc994ad2dc26f932dbddc508ded57ad48bf938dc4e1a?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/6f93f7901e679dc73c0ebc994ad2dc26f932dbddc508ded57ad48bf938dc4e1a?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/6f93f7901e679dc73c0ebc994ad2dc26f932dbddc508ded57ad48bf938dc4e1a?s=96&d=mm&r=g","caption":"Julie"},"url":"https:\/\/www.candoifp.com\/blog\/author\/jheltunen\/"}]}},"_links":{"self":[{"href":"https:\/\/www.candoifp.com\/blog\/wp-json\/wp\/v2\/posts\/533","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.candoifp.com\/blog\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.candoifp.com\/blog\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.candoifp.com\/blog\/wp-json\/wp\/v2\/users\/4"}],"replies":[{"embeddable":true,"href":"https:\/\/www.candoifp.com\/blog\/wp-json\/wp\/v2\/comments?post=533"}],"version-history":[{"count":11,"href":"https:\/\/www.candoifp.com\/blog\/wp-json\/wp\/v2\/posts\/533\/revisions"}],"predecessor-version":[{"id":717,"href":"https:\/\/www.candoifp.com\/blog\/wp-json\/wp\/v2\/posts\/533\/revisions\/717"}],"wp:attachment":[{"href":"https:\/\/www.candoifp.com\/blog\/wp-json\/wp\/v2\/media?parent=533"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.candoifp.com\/blog\/wp-json\/wp\/v2\/categories?post=533"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.candoifp.com\/blog\/wp-json\/wp\/v2\/tags?post=533"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}